Custom linear lighting · Continuous runs

Continuous linear runs, planned section by section

A long, seamless line of light is really a set of joined sections, corners, feeds and drivers. Getting the plan right is what makes it look continuous.

Short answer

A continuous linear run is made from factory sections joined end to end, plus corner modules where the run turns. To make it work, plan four things: the section breakdown that adds up to the required length within tolerance, the corners (L, T, X), the power feed points, and the drivers, each sized to the load it carries with headroom. Field-verify critical dimensions before release when the room is not built yet.

Key takeaways

  • Total run length = sum of sections + corners + end caps, within the manufacturer’s tolerance.
  • Every driver is sized to its connected load with headroom (commonly loaded to about 80%).
  • More feeds mean shorter circuits and less voltage drop.
  • Wall-to-wall runs need a field dimension check before release.

Anatomy of a continuous run

Component Role
Sections Factory lengths joined end to end; may be lit or unlit
Joiners / alignment splines Keep sections straight and light seams minimal
Corners (L, T, X) Turn the run; lit or unlit
End caps Close the run; add a few millimetres at each end
Feed kits Where mains or low-voltage power enters the run
Drivers Integral in the housing or remote, each sized to its load
Mounting Suspension kits, recessed brackets or surface clips at set spacing

Worked example: section breakdown

Target: a 30 ft 0 in wall-to-wall recessed run, sections available in 1 ft increments up to 8 ft, end caps 0.25 in each.

  1. Allow for end caps: 30 ft − 0.5 in = 29 ft 11.5 in available for sections.
  2. Choose sections: 8 + 8 + 8 + 5 = 29 ft.
  3. Remaining 11.5 in: use a 1 ft filler if the manufacturer offers one that can be ordered short, or adjust the ends with trim.
  4. Confirm the as-built wall dimension on site before release.

Feeds and drivers

Each driver can power a limited load, and each circuit a limited current. Split long runs into zones and feed each one. The load per zone is:

zone load (W) = lit length (ft) × wattage per foot (W/ft)

Choose a driver whose rated power is comfortably above that load. See how to size an LED driver for the full method, and 24V vs 48V for how voltage affects run length on low-voltage systems.

Related

Frequently asked questions

What is the maximum length of a continuous linear run?

There is no single limit for the run; the limit is per circuit and per feed. Long runs are broken into electrical zones, each fed and driven separately, while the housing stays continuous. The manufacturer’s maximum length per feed sets how many feeds are needed.

How do linear lighting corners work?

Corner modules (L, T or X) join straight sections at an angle. Some are lit to keep the line of light continuous through the corner; others are unlit connectors. The corner’s own dimensions count toward the run length.

What tolerance should I allow for wall-to-wall runs?

Allow for both the building tolerance and the product tolerance per section. Many manufacturers offer a filler or adjustable end section to absorb the difference.

Send us the spec. We will do the matching.

Upload a fixture schedule, a spec section or a drawing set. You get a line-by-line match, alternates and a quote back from a person who knows lighting.